DS-B 1-3KVA
An Online UPS is not a further improvement of the standby technology, but a completely different approach to providing the highest level of power supply. A double-conversion refers to converting the incoming AC power into DC power, and inverting it back to AC power. This ensures the newly reproduced power to be of a quality standard set by UPS, to be completely cleared of all imperfections of the power coming from the AC mains. Regardless of what is going on the AC mains side, the UPS output voltage, frequency and signal purity are kept up to the highest standards. The current flow is absolutely uninterruptible, the transfer time is zero. The UPS can work in pair with diesel generator, and can accommodate additional battery cabinets for a longer backup time.
Beside those, the Durable Series UPS offer a set of essential features that make these UPS a flexible power supply control and power saving tool.
By now the Durable Series UPS perfectly serve their purpose in numerous data processing, medical, banking and other mission critical centres around the globe.
Model Name | DS1000B | DS1500B | DS2000B | DS3000B | |
Topology | True On-Line, Double Conversion, High Frequency | ||||
On-battery Output Waveform | Pure Sine Wave | ||||
Maximum Capacity | 1000VA / 700W | 1500VA / 1050W | 2000VA / 1400W | 3000VA / 2100W | |
INPUT | |||||
Nominal Input Voltage | 100 / 110 / 120Vac or 220 / 230 / 240Vac | ||||
Nominal Input Frequency | 50Hz / 60Hz Auto Sensing | ||||
Input Voltage Range | 80-144Vac (100 / 110 / 120Vac) or 160-276Vac (220 / 230 / 240Vac) | ||||
OUTPUT | |||||
Nominal Output Voltage | 100 / 110 / 120 / 127Vac or 220 / 230 / 240Vac (selectable) | ||||
Output Voltage Regulation | Rated Voltage ±2% (on battery) | ||||
Transfer Time (Typical) | 0 ms | ||||
Start on Battery | Yes | ||||
Auto Restart | Yes | ||||
Number of Outlets | 6 Battery backup (NEMA 15A) | 12 Battery backup (NEMA 15A) | 12 Battery backup (NEMA 15A) | ||
4 Battery backup (IEC 10A) | 9 Battery backup (IEC 10A×8 / 16A×1) | ||||
PROTECTION | |||||
Data Line Surge Protection | RJ11 / RJ45 | ||||
Surge Energy Rating | 125 Joules (100 / 110 / 120Vac) or 280 Joules (220 / 230 / 240Vac) | ||||
Overload Protection | UPS shuts down at 110% load after 10 secs or 130% load after 1.5 secs | ||||
Over Current Protection | Circuit Breaker | ||||
Discharge Protection | Keylock | ||||
BATTERY | |||||
Configuration | 36V (12V 7.2AH×3) | 36V (12V 34W×3) | 72V (12V 7.2AH×6) | 72V (12V 34W×6) | |
Backup Time (Full / Half load) | 6 / 18 min | 5 / 15 min | 6 / 18 min | 5 / 15 min | |
Recharge Time to 90% (Typical) | < 4 Hours | ||||
Extended Battery Pack (Optional)* | BP1000 | BP1500 | BP2000 | BP3000 | |
12V 7.2AH×6 | 12V 34W×6 | 12V 7.2AH×12 | 12V 34W×12 | ||
ADVANCED WARNINGS / DIAGNOSTICS | |||||
Front Panel | AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Status | ||||
Audible Alarms | Battery mode / UPS faults / Overload | ||||
COMMUNICATION INTERFACE | |||||
Communication Port | RS232 and USB# | ||||
SNMP Manageable | Yes | ||||
ENVIRONMENTAL | |||||
Operation Temperature | 0~40°C / 32~104°F | ||||
Storage Temperature | -20~60°C / -4~140°F | ||||
Relative Humidity | 0~95% Non condensing | ||||
Audible Noise | <40dBA | ||||
PHYSICAL | |||||
Dimensions Physical / Packing (L×W×H ) | in | 16.5×6×9.4 / 21.5×11×14 | 16.5×8.9 ×14.1 / 20.7×13.8×19.1 | ||
mm | 420×152×238 / 545×280×355 | 420×225×358 / 526×350×485 | |||
Weight (Net / Gross) | lbs | 36.4 / 40.6 | 37.7 / 41.9 | 68.5 / 74.1 | 72.8 / 78.3 |
kg | 16.5 / 18.4 | 17.1 / 19 | 31.1 / 33.6 | 33 / 35.5 | |
Battery Pack Physical / Packing (L×W×H ) | in | 16.5×6×9.4 / 21.5×11×14 | 16.5×8.9 ×14.1 / 20.7×13.8×19.1 | ||
mm | 420×152×238 / 545×280×355 | 420×225×358 / 526×350×485 | |||
Battery Pack (Net / Gross) | lbs | 46.7 / 50 | 88.4 / 98.4 | ||
kg | 21.1 / 22.6 | 40 / 44.5 | |||
CONFORMANCE | |||||
Approvals | UL / cUL, CE, GOST-R |