TS-B 1-2KVA
Line interactive design
Boost and buck AVR (Auto Voltage Regulation)
Fully digitized microprocessor control
Energy saving function (UPS green mode)
50 / 60 Hz frequency auto sensing and selection
Cold start function (DC power on)
Short circuit and overload protection
RS232 communication port**
Tel / Modem / LAN surge protection**
History record of power failure events**
Smart power management software**
Scheduled shutdown & reboot**
(**Features of TSB models only)
| Model Name | TS1250B | TS1700B | TS2250B | |
| Topology | Line-Interactive, Low Frequency | |||
| On-battery Output Waveform | Simulated Sine Wave | |||
| Maximum Capacity (VA / W) | 1000VA / 600W | 1500VA / 900W | 2000VA / 1200W | |
| INPUT | ||||
| Nominal Input Voltage | 110 / 120 or 220 / 230 / 240Vac(!!) | |||
| Nominal Input Frequency | 50Hz / 60Hz Auto Sensing | |||
| Input Voltage Range | Rated Voltage ±25% | |||
| OUTPUT | ||||
| Nominal Output Voltage | 110 / 120 or 220 / 230 / 240Vac(!!) | |||
| Output Voltage Regulation | Rated Voltage ±5% (on battery) | |||
| Transfer Time(Typical) | 4 ms | |||
| Start on Battery | Yes | |||
| Auto Restart | Yes | |||
| Automatic Voltage Regulation (AVR) | AVR increases the output voltage by 15% while the input voltage decreases by 9 % to 25 % | |||
| AVR decreases the output voltage by 13% while the input voltage increases by 9 % to 25 % | ||||
| Number of Outlets | 4 Battery backup + 1 Bypass (IEC 10A) | 4 Battery backup + 1 Bypass (IEC 10A) | 5 Battery backup (IEC 10A) | |
| 4 Battery backup + 1 Bypass (NEMA 15A) | 5 Battery backup (NEMA 15A) | 5 Battery backup (NEMA 15A) | ||
| PROTECTION | ||||
| Data Line Surge Protection | RJ11 / RJ45 | |||
| Surge Energy Rating | 1185 Joules (NEMA modules) | |||
| Overload Protection | UPS shuts down at 110% load ater 60 secs or 130% load after 3 secs | |||
| Over Current Protection | Fuse (Circuit breakers for TS1250 / 1700 models with NEMA outlets) | |||
| Discharge Protection | Keylock | |||
| BATTERY | ||||
| Configuration | 24V (12V 7.2AH×2) | 24V (12V 34W×2) | ||
| Typical Backup Time** | 42 min | 45 min | ||
| Recharge Time to 90% (Typical) | < 4 Hours | |||
| ADVANCED WARNINGS / DIAGNOSTICS | ||||
| Front Panel LEDs | AC Mode / Battery Mode / Battery Fault / Overload | |||
| Audible Alarms | Battery Mode / Battery Low / Overload | |||
| COMMUNICATION INTERFACE | ||||
| Communication Port | RS232*2 | RS232 *2 for 220 / 230 / 240V models | ||
| USB*1 for 110 / 120V models | ||||
| ENVIRONMENTAL | ||||
| Operation Temperature | 0~40°C / 32~104°F | |||
| Storage Temperature | -20~60°C / -4~140°F | |||
| Relative Humidity | 0~95% Non condensing | |||
| Audible Noise | < 40 dBA | |||
| PHYSICAL | ||||
| Dimensions Physical / Packing (L×W×H) |
in | 15×5.1×7.5 / 19.1×9.6×12.2 | ||
| mm | 382×130×192 / 485×244×310 | |||
| Weight (Net / Gross) | lbs | 28.6 / 32.6 | 35.0 / 38.0 | |
| kg | 13.4 / 14.8 | 15.9 / 17.3 | ||
| CONFORMANCE | ||||
| Approvals | UL / cUL, CE | |||