Brand: Nguồn điện liên tục - Opti UPS

PS-D-RT 3-10KVA

The PSB Series are the only line interactive pure sinewave UPS designed to meet everyone''s needs. The full range capacity covers every possible application demand.

Every PSB model utilizes digital line interactive technology that incorporates AVR.

AVR: (Automatic Voltage Regulator) Stabilizes all currents from over and under voltages, so that only the most clean and safe currents feed into your equipment. 

Every single model is equipped with our full version of OPTI-SAFE control software. 

Sine wave: Represents energy entirely concentrated at a single frequency. The more concentrated the energy is the cleaner and safer the current will be. Fluctuations in energy called sags, brownouts and spikes, are harmful to machines and systems

Model Name PS3000D-RT PS5000D-RT PS7500D-RT PS10000D-RT
Topology Line-interactive, Low Frequency
On-battery Output Waveform Pure Sine Wave
Maximum Capacity 3000VA / 1875W 5000VA / 3125W 7500VA / 4688W 10KVA / 6250W
UPS Type Tower & Rack Convertible
Cabinet Type 3U Rack & Tower Convertible
INPUT
Nominal Input Voltage 110 / 120Vac or 220 / 230 / 240Vac(!!)

220 / 230 / 240Vac(!!)

Nominal Input Frequency 45~70Hz Auto Sensing
Input Voltage Range 85Vac ~ 150Vac or 170Vac ~ 300Vac 170Vac ~ 300Vac
OUTPUT
Nominal Output Voltage 110 / 120Vac or 220 / 230 / 240Vac re-settable via LCD panel 220 / 230 / 240Vac re-settable via LCD panel
Output Voltage Regulation Rated Voltage ±3% (on battery)
Transfer Time (Typical) 4 ms
Start on Battery Yes
Auto Restart Yes
Automatic Voltage Regulation(AVR) Yes
Number of Outlets 8 Battery backup (NEMA 15A) 8 Battery backup (NEMA 15A) + 1 terminal block 4 Battery backup (NEMA 15A) + 1 terminal block
10 Battery backup (IEC 10A) 10 Battery backup (IEC 10A)+ 1 terminal block 5 Battery backup (IEC 10A)+ 1 terminal block
PROTECTION
Data Line Surge Protection RJ11
Overload Protection UPS shuts down at 135% load after 30 secs or 150% load after 200m secs
Over Current Protection Circuit breaker
Discharge Protection Keylock
BATTERY
Configuration 36V (12V / 7.2AH×3) / 2sets 48V (12V / 9AH×4) / 2sets 48V (12V / 7.2AH×4) / 4 sets 48V (12V / 9AH×4) / 4sets
Backup Time (Full / Half load) 4 / 11min 3 / 11min 4 / 12 min 3 / 12 min
Recharge Time to 90% (Typical) < 4 Hours
ADVANCED WARNINGS / DIAGNOSTICS
Front Panel LCD: UPS status, I/P & O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model
LED: Normal (Green), Warning (Amber), Fault (Red)
Audible Alarms Battery mode / UPS fault / Overload
COMMUNICATION INTERFACE
Communnication Port RS232 (Optional interface of USB, Dry Contact, SNMP, RS485, AS400, Modbus or Remote Control)
ENVIRONMENTAL
Operation Temperature 0~40°C / 32~104°F
Storage Temperature -20~60°C / -4~140°F
Relative Humidity 0~95% Non condensing
Audible Noise < 45 dBA
PHYSICAL
Dimensions
Physical / Packing (W×H×D)
in 17.6×5.28×18.6 / 28.8×16×21.6 17.6×5.28×24.8 / 28.8×16×21.6 17.6×5.28×18.6 / 28.8×16×21.6
mm 440×132×465 / 720×400×540 440×132×620 / 720×400×540 440×132×465 / 720×400×540
Weight (Net / Gross) lbs 81.5 / 92.6 110 / 134.3 69.8 / 91.5 172.6 / 196.5
kg 36.9 / 41.9 49.8 / 60.8 31.6 / 41.4 78.1 / 88.9
Share: