• True galvanic isolation design ensures that such serious AC mains problems as noise, lightning effects or leakage current do not reach your systems.
• Protection from the accidental disconnection of the neutral wire ensures the safety of the UPS and the stability of the power supply.
• Protection from incorrect operation ensures that violating the operation procedures will not lead to UPS or connected equipment damage.
• The use of up-to-date DSP, IGBT and switching components ensures the high reliability and efficiency of the UPS.
• Multi-CPU design increases the system reliability.
• Plug-and-play design and easy access to boards ensures the fastest and easiest UPS maintenance.
• Individual inverter for each phase ensures stable work under completely unbalanced load.
• Intelligent charger with temperature compensation feature ensures the longest possible battery life. The adjustable level of charging current allows the UPS to work with large battery banks for long backup time.
• Intelligent battery test logics eliminate the possibility of power supply interruption during battery test in case of batteries being bad. Provides the detection of battery electrolyte leakage and improper battery grounding.
• Intelligent fan speed control increases the fan life expectancy and reduces the audible noise.
• Advanced heat abstraction design by physical separation of the power and control circuitry ensures the smooth operation of the UPS under most harsh conditions.
• Cold start function makes it possible to start the UPS even when AC mains are not providing the power.
• 12-pulse rectifier ensures reduced harmonics for UPS with capacities of 80KVA and higher.
• Input harmonic filter reduces the Total Harmonic Distortion (T.H.D.) of the UPS.
• Parallel operation makes it possible to upgrade the UPS to a larger capacity.
Model Name | DS10KD33 | DS15KD33 | DS20KD33 | DS30KD33 | DS40KD33 | DS50KD33 | DS60KD33 | |
Topology | True On-Line, Double Conversion | |||||||
On-battery output Waveform | Pure Sine Wave | |||||||
Maximum Capacity | 10KVA / 8KW | 15KVA / 12KW | 20KVA / 16KW | 30KVA / 24KW | 40KVA / 32KW | 50KVA / 40KW | 60KVA / 48KW | |
INPUT | ||||||||
Nominal Input Voltage | 380 / 400 / 415Vac | |||||||
Input Phase and Wire | 3 Phase 4 Wire and ground | |||||||
Nominal Input Frequency | 50 / 60 Hz ± 7% | |||||||
Input Voltage Range | Rated Voltage ± 20% | |||||||
Rectification Pulse | 6 pulses or 12 pulses (optional) | |||||||
OUTPUT | ||||||||
Output Voltage | 380 / 400 / 415Vac | |||||||
Output Phase and Wire | 3 Phase 4 Wire and ground | |||||||
Nominal Output Frequency | 50Hz / 60Hz | |||||||
Frequency Lock Range | ±5 Hz | |||||||
THD (Linear Load) | < 5 % | |||||||
Output Voltage Regulation | Rated Voltage ± 1% | |||||||
Transfer Time (Typical) | 0 ms | |||||||
Start on battery | Yes | |||||||
Auto Restart | Yes | |||||||
STATIC SWITCH | ||||||||
Operation | UPS bypasses as the inverter and the utility are synchronized | |||||||
Efficiency | 99.50% | |||||||
CHARGER | ||||||||
Voltage | 397V | |||||||
Current | 1A | 1.5A | 2A | 3A | 4A | 5A | 6A | |
Charge Time to 90% (Typical) | <4 Hours | |||||||
BATTERY | ||||||||
Configuration | Battery Pack with 12V×29 pcs | |||||||
Backup time | Depends on overall battery capacity | |||||||
PROTECTIONS | ||||||||
Overload Protection | UPS shuts down at 110% load after 15 mins, at 135% load after 10 mins or 150% load after 30 secs | |||||||
Over Current Protection | Circuit breaker | |||||||
ENVIRONMENTAL | ||||||||
Operation Temperature | 0~40°C / 32~104°F | |||||||
Storage Temperature | -25~55°C / -13~130°F | |||||||
Ambient operation | 0 - 95% Non condensing | |||||||
Audible Noise | < 60 dBA | |||||||
PHYSICAL | ||||||||
Dimensions Physical / Packing (L×W×H) |
in | 31.5×21.7×63 / 37.4×27.6×73.6 | ||||||
mm | 800×550×1600 / 950×700×1870 | |||||||
Weight (Net / Gross) | lbs | 661 / 738 | 793 / 870 | 881 / 958 | 1035 / 1112 | 1145 / 1222 | 1233 / 1311 | 1388 / 1465 |
kg | 300 / 335 | 360 / 395 | 400 / 435 | 470 / 505 | 520 / 555 | 560 / 595 | 630 / 665 |