DS-B-RMP 6-10KVA
• Online double conversion design
• Pure sine wave output with less than 3% THD
• Fully digitized microprocessor control
• Power factor correction
• Selectable UPS output voltage
• High efficiency mode
• Cold start function (DC power on)
• Emergency power off function (EPO)
• Short circuit and overload protection
• Fax / Modem / LAN data line surge protection
• Advanced battery management (ABM)
• Automatic battery charging in UPS OFF mode
• Automatic diagnostics and battery check-up
• Extended battery pack available
• Multilanguage LCD display
• RS232 and USB Communication ports, UPS monitoring software
| Model Name | DS6KB-RMP | DS10KB-RMP | |
| Topology | True On-Line, Double Conversion, High Frequency | ||
| On-battery Output Waveform | Pure Sine Wave | ||
| Maximum Capacity | 6000VA / 4200W | 10000VA / 7000W | |
| Cabinet Type | 3U Machine + 3U Battery Pack | ||
| INPUT | |||
| Nominal Input Voltage | 220 / 230 / 240Vac | ||
| Input Voltage Regulation | 176-276Vac | ||
| Nominal Input Frequency | 50Hz / 60Hz Auto Sensing | ||
| Parallel function (Total Parallel Number) | Parallel up to 3 units (Total 4 units including mainframe) | ||
| OUTPUT | |||
| Nominal Output Voltage | 220 / 230 / 240Vac | ||
| Output Voltage Regulation | Rated Voltage ±2% (on battery) | ||
| Transfer Time | 0 ms | ||
| Start on Battery | Yes | ||
| Auto Restart | Yes | ||
| PROTECTION | |||
| Data Line Surge Protection | NA | ||
| Overload Protection | UPS shuts down at 130% load after 10 secs or 150% load after 2 secs | ||
| Over Current Protection | Circuit Breaker | ||
| Discharge Protection | Keylock | ||
| BATTERY | |||
| Backup Time (Full / Half load) | 7 / 14 min | 4 / 12 min | |
| Recharge Time to 90% (Typical) | < 4 Hours | ||
| Extended Battery Pack* | BP6000-RM | BP10000-RM | |
| 240V | 240V | ||
| (12V / 7.2AH×20) | (12V / 9AH×20) | ||
| ADVANCED WARNINGS / DIAGNOSTICS | |||
| Front Panel | On / On Line / On Battery / Bypass / Fault and 15-UPS status | ||
| Audible Alarms | Battery Mode / Battery Test / Replace Battery / Low Battery / UPS fault / Overload | ||
| COMMUNICATION INTERFACE | |||
| Communication Port | RS232 & USB# | ||
| SNMP Manageable | Yes | ||
| ENVIRONMENTAL | |||
| Operation Temperature | 0°~40°C / 32°~104°F | ||
| Storage Temperature | -15°~50°C / 5°~122°F | ||
| Relative Humidity | 0~95% Non condensing | ||
| Audible Noise | < 55 dBA | ||
| PHYSICAL / DS-B-RM | |||
| Dimensions Physical / Packing (L×W×H) |
in | 26.4×16.9×5.1 / 32.7×22×11.0 | |
| mm | 672×428×130 / 819×566×280 | ||
| Weight Net / Gross |
lbs | 50.7 / 59.5 | |
| kg | 23 / 27 | ||
| PHYSICAL / DS-BP-RM | |||
| Dimensions Physical / Packing (L×W×H) |
in | 23.5×16.9×5.1 / 28.7×21.5×14.5 | |
| mm | 597×428×130 / 740×560×370 | ||
| Weight Net / Gross |
lbs | 145.5 / 166.5 | |
| kg | 66 / 75.5 | ||
| CONFORMANCE | |||
| Approvals | CE | ||